  • IGBT Explained
    IGBT's (insulated-gate bipolar transistors) are used in modern Uninterruptible Power Supplies (UPS) combining high efficiency with fast switching whilst keeping the frequency output without narrow tolerances. Stable seamless electrical power supply. IGBT provide extremely low voltage distortion and improves the power efficiency especially when supporting...
  • Peak Lopping Explained
    Peak load lopping also known as ‘peak load shaving’ & ‘load sharing’, is the used when the GRID supply can’t be increased due to cost or location and you need more power than is available. When the more power is required and the GRID can’t...
  • Generator Frequency Fluctuation
    Generator frequency fluctuation can occur when the generator is under load. The diesel engine can he heard to be struggling or hunting randomly. If this audible fluctuation continues you may find that on the control panel you can see the frequency drop and rise erratically....
  • Data Centre Cooling Air Conditioning Installation
    Traditionally, there are two ways of cooling a data center: air-based cooling and liquid-based cooling. Air-Based The first and most common, method within the realm of air-based cooling is what’s called ‘cold aisle/hot aisle.’ The idea is to separate the cold air from the hot...
  • Data Centre Fire Suppression Installation Upgrade
    Facility managers have a range of factors to consider when it comes to data center fire suppression systems. The primary fire protection systems used within data centers typically include: wet pipe sprinklers, pre-action sprinklers, and special suppression (i.e., clean agent, inert gas, or mist)  Facility managers have a range of factors to consider when it...
  • Generator AVR – What is the AVR?
    The Generator AVR is a small electronic device that sits on the alternator monitoring the power output. You may never even notice it. This small electronic device automatically maintains the generator electrical output terminal voltage within pre-set manufacturers parameters. The Automatic Voltage Regulator (AVR) is...
  • Generator Hunting and Surging
    Generator hunting and surging randomly or erratically. This can occur when the generator is under load and has been running perfectly normally then suddenly your generator struggles. You’ll first become aware of this , because you’ll hear the engine struggling or hunting randomly. Check the...
  • eBay parts won’t save you
    Does eBay provide your only opportunity for spare parts for aged equipment? Can’t get parts anymore, not even from Ebay? eBay, your last hope for spare parts has failed you? Ever needed parts Urgently? And can’t get them from anywhere? Not even eBay? eBay spare...
  • Deep Sea Controller – How To Isolate A Generator
    How to turn the generator OFF and NON operational - (How to isolate generator) To place into manual mode Press the hand button:  on the control panel. Then press the red stop button:   on the control panel The display will say "genset at rest" in manual mode. And then go...
  • Deep Sea Controller – How To Test A Generator WITH Load – DSE 7310
    Using the Generator Control Panel In the Plant Room Generator – at all times the generator is in Auto Generator control panel Auto button This button red light must always lit to ensure the generator remains in automatic mode ready to take load during any power outage. Monthly ON Load Test...
  • Deep Sea Controller – How To Test A Generator OFF Load – Weekly – DSE 6110
    HOW TO PERFORM A MANUAL OFF LOAD TEST   1. Turn Breaker on the Generator to OFF position 2. Press Manual Mode button on display ONCE only 3. Check Manual Mode LED is lit 4. Check Display Reads Manual Mode. 5. PRESS GREEN Start Button for Approx 2 seconds Engine will start up and begin the OFF load test Close generator...
  • Deep Sea Controller – DSE 3110
  • Deep Sea Controller – Buttons Explained
  • Diesel Generator Won’t Start – Tried Everything
    Diesel generator still won’t start? Then we need to look at the ‘not-so-obvious’ and check them carefully, one by one. Firstly check through all the advice that Power Continuity has provided within our FREE knowledge resource base listed below:- https://powercontinuity.co.uk/knowledge-base/diesel-generator-wont-start/ https://powercontinuity.co.uk/knowledge-base/generator-failed-start/ https://powercontinuity.co.uk/knowledge-base/diesel-generators-what-about-temperature-issues/ https://powercontinuity.co.uk/knowledge-base/generator-overheating/ Now let’s...
  • Data Centre Power Continuity
    Data Centre Power Continuity will eliminate power dips, spikes, brownouts that would otherwise pose a serious risk to data centre IT equipment and servers. Additionally, multiple issues can be experienced when data centre power has blips, including loss of data, reduced production and time wasted...